Featured Flow Equipment

FLUXUS® F721 - The ultrasonic flow meter for permanent installation

With one or two flow channels and versatile electrical inputs and outputs, Ethernet and USB, the FLUXUS F721 can optimally be configured to your application needs, measuring and handling a variety of process parameters.

 

The FLUXUS F721 features a robust metal field housing. Its clamp-on flow transducers are simply mounted onto the pipe from the outside and are thus installed quickly, without any process interruption and without any production stop.

 

Since the flowmeter's transducers are not in contact with the medium to be measured, they are not submitted to wear and tear. Transducers for the common pipe diameters (0,25 to 500 inches feet) and temperatures ranges (from -275°F to 1100°F) as well as hazardous zones (FM and ATEX) are available.

 

The measurement is pressure independent and can take place on pipes of almost any materials and on almost any liquid.

 

The flowmeter is the ideal instrument for monitoring chemically aggressive, toxic or just media that you want to keep inside the pipe.

 

Thanks to its exceptional dual-uP technology, the high number of measuring cycles per second, and the adaptive signal processing, the FLUXUS® F721 produces stable and reliable measuring results even under difficult conditions.

 

No zeroing procedure is necessary at the commissioning since all transducer pairs are factory calibrated and the calibration data is permanently stored in the transducers themselves (EPROM).

 

An extended status display helps the user to judge the measuring situation and the current accuracy directly during the measurement.

 

The FLUXUS F721 is delivered with one or two flow measurement channels. Additionally, it can be equipped with various outputs and up to 4 process inputs. The input quantities (e.g. temperature or pressure) can be used by the flowmeter together with the measured flow for the calculation of further quantities: e.g. energy, mass flow, etc.

FLUXUS F721 Stainless Steel housed flow meter -
withstanding the harshest environments including Offshore

The FLUXUS F721 offers all the benefits as our standard FLUXUS flow meters but in a corrosion resistant Stainless Steel 316L / 1.4404 housing, ideal for any application where the flow meter is exposed to high humidity, moisture and corrosive coastal environments as well as offshore.

The FLUXUS F721 flow meter allows for an inherently precise bi-directional, highly dynamic flow measurement of volume and mass flow rates of virtually any liquid media - from crude oil to refined products as well as chemicals - and can be equipped with various outputs to be used for a sophisticated process control. The FLUXUS F721 liquid flow meter is also available as a gas flow meter, the FLUXUS G7721!

As the ultrasonic transducers are mounted on the outside of the pipe wall, enclosed in the rugged stainless steel PermaLok mounting fixture, the system does not suffer from wear, tear or clogging and can‘t be a risk for leaks.

And with the same matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME regulations), the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducers calibration data is automatically loaded by connecting the transducer to the transmitter,set-up times are significantly reduced. 

Leveraging its exceptional dual-μP technology, the high number of measuring cycles per second and the adaptive signal processing, the FLUXUS F721 flow meter produces stable and reliable measuring results under extreme environmental conditions.​

FLUXUS F601 - The Portable Flow Meter

The FLUXUS F601 is the portable clamp-on flow meter of choice for servicing and maintenance activities, the control and auditing of measurement points not covered by permanent meters, or even the temporary replacement of permanently installed flow meters.

 

The FLUXUS F601 is measurement ready in less than 5 minutes, including the measurement of the pipe wall thickness, the connection of the transducers to the transmitter, the parameterization of the flow meter and finally the mounting of the transducers.

 

The F601 was designed to easily withstand rough industrial environments. Besides its sturdy housing, the F601 portable flow meter features stable and precise push-pull transducer connectors with armored cables to prevent breaking or rupturing during daily work. 

 

With its Li-Ion battery, the F601 allows for up to 14 hours of autonomous measurement. Matched and paired transducers, as well as sophisticated algorithms, care for the correction of pipe wall echoes and a wrong transducer positioning, thus ensuring reliable and highly accurate measurements - even during the most demanding application conditions.

 

The FLUXUS F601 portable clamp-on flow meter is also available in an "Energy" and"Multifunctional" version , allowing the measurement of thermal energy / BTU flows and making the flow meter the ideal companion for the analysis or auditing of heating and chiller plants.

FLUXUS F608 - The Portable Flow Meter

The new FLUXUS F608 is based on the widely used, highly reliable and versatile F601, but has been specifically engineered for its use within hazardous areas and is FM Class I, Div. II approved.

 

Thus, users are not anymore obliged to obtain a Hot Work Permit, making the access to hazardous areas much easier and less time consuming.

 

The extremely resistant carbon fiber housing, together with the rugged transducer design, ensures a high impact protection as well as resistance against oil, water and many other liquids. The F608 shares the same efficient battery management as the F601, offering over 14 hrs. of remote measurement time.

 

Moreover, the measurement system can be fully set-up in less than five minutes due to the intuitive user guidance and the automatic transducer recognition. Its application range is unrivalled - from pipes as small as 0.4 up to 255 inches inner diameter and temperatures ranging from -40°F to 392°F (with the WaveInjector solution even from -256°F to 840°F).

 

Being equipped with two flow channels, multiple In- and Outputs and an integrated data logger with a serial interface, the flowmeter is designed for direct usage in demanding environments, such as in the Upstream, Midstream and Downstream area as well as in the processing industries and the energy sector.

 

As known from all FLEXIM flow meters, also the F608 features a highly precise bi-directional measurement at fast and even very slow flow rates over a wide dynamic measurement range and is not prone to temperature and zero drift, being fully compliant to ANSI/ASME regulations.

FLUXUS G721 - The Stationary Gas Meter

The FLUXUS G721 is FLEXIM's gas flow meter for permanent installation in nearly any gas flow metering application. Its non-intrusive measurement technology ensures a precise bi-directional, highly dynamic gas flow measurement of operational and standard volume flows.

 

As the transducers are mounted on the outside of the pipe wall in rugged mounting fixtures, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.

 

Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducer calibration data is automatically loaded by connecting the transducer to the transmitter, set-up times are reduced and precise, long-term stable results are provided.

 

The gas flow meter can be applied at inner pipe diameters ranging from 0.4 to 83 inches (no limitations on pipe wall thickness or material) and media temperatures from -40 °F to 210 °F. Moreover, the measurement system is independent of the pressure inside the pipe.

With up to two measurement channels, the FLUXUS G721 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as dust and humidity. Even wet gas up to Liquid Volume Fractions of 5% can be measured.

 

The FLUXUS G721 gas flow meter is also available in an ATEX Zone 2 / FM Class I, Div. 2 approved version, allowing its usage in the respective hazardous areas. FLEXIM also offers gas flow meters for usage in FM Class I, Div. 1 / 2 or ATEX Zone 1 environments, such as the FLUXUS G809 and FLUXUS G801 (for offshore usage).

 

 

 

FLUXUS G721 Stainless Steel housed gas flow meter - 
withstanding the harshest environments including Offshore

The FLUXUS G721 offers all the benefits as our standard FLUXUS gas flow meters but in a corrosion resistant Stainless Steel 316 housing, ideal for any application where the flow meter is exposed to high humidity, moisture and corrosive coastal environments as well as offshore.

The FLUXUS G721 flow meter allows for an inherently precise bi-directional, highly dynamic gas flow measurement of operational and standard volume flow rates of virtually any gaseous media - from (wet) natural gas, to gas processing and transport as well as over to the broad spectrum of gases used within the chemical industry.

As the ultrasonic transducers are mounted on the outside of the pipe wall, enclosed in the rugged stainless steel PermaLok mounting fixture, the system does not suffer from wear and tear or clogging, can‘t be a risk for leaks and will not cause any pressure drops inside the pipe.

And with the same matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME regulations), the measurement system is drift free and zero stable ensuring accurate readings. Moreover, as the transducers calibration data is automatically loaded by connecting the transducer to the transmitter,set-up times are significantly reduced and precise, long-term stable results are provided. 

Leveraging its exceptional dual-μP technology, the high number of measuring cycles per second and the adaptive signal processing, the FLUXUS G721 gas flow meter produces stable and reliable measuring results even under extreme environmental conditions. With one or two flow channels and versatile electrical inputs and outputs, the FLUXUS G721 can optimally be configured to your application needs, measuring and handling a variety of process parameters.

 

The G721 gas flow meter can be applied at inner pipe diameters ranging from a 10mm up to 2100 mm (no limitations on pipe wall thickness or material) and media temperatures from -40 °C to 100 °C. Moreover, the measurement system is independent of the pressure inside the pipe!

 

With up to two measurement channels, the FLUXUS G721 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as dust and humidity. Even wet gas up to Liquid Volume Fractions of 5% can be measured.

FLUXUS G601 - Portable Gas Flow Meter

The FLUXUS G601 portable gas flow meter measures the flow of nearly any gas using FLEXIM's proven transit-time correlation technique.


Special ultrasonic Lamb and shear wave transducers are simply clamped onto the outside of the pipe, thus no cutting into the pipe or process interruption is required for installation.

 

The FLUXUS G601 portable gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe. It is the ideal tool for servicing and maintenance activities, the control and auditing of measurement points not covered by permanent meters, or even the temporary replacement of permanently installed gas flow meters.

 

Though featuring an ergonomic design, which offers simple handling and maximum ease of use, the G601 was designed to easily withstand rough industrial environments. Besides its sturdy housing, the G601 portable gas flow meter features stable and precise push-pull transducer connectors with the cables themselves being steel armored to prevent breaking or rupturing during daily work.

FLUXUS G608 - Portable Gas Flow Meter

The new FLUXUS G608 portable gas flow meter is based on the widely used, highly reliable and versatile G601, but has been specifically engineered for its use within hazardous areas and is FM Class I, Div. II approved.

 

It is the ideal solution for gas flow measurement in potentially explosive areas, may it be for a temporary replacement of a stationary flow meter, check metering or service operations. Due to its certification, users are not anymore obliged to obtain a Hot Work Permit, making the access to hazardous areas much easier and less time consuming.

 

The extremely resistant carbon fiber housing, together with the rugged transducer design, ensures a high impact protection as well as resistance against oil, water and many other liquids. The G608 portable gas flow meter shares the same efficient battery management as the G601, offering over 14 hrs. of remote measurement time.

 

Moreover, the measurement system can be fully set-up in less than five minutes due to the intuitive user guidance and the automatic transducer recognition. Its application range is unrivalled - from pipes as small as 0.28 up to 63 inches inner diameter and temperatures ranging from 14°F to 392°F.

logo_tricor_RGB_254x95.jpg

TRICOR Coriolis Technology Flow Meter

When you combine decades of experience with truly unique talents, great things can happen. TRICOR Coriolis Technology engineers have been intimately involved with the development and evolution of Coriolis flow instrumentation since the beginning. In fact, many of the critical patents for Coriolis technology bear our engineers’ names.

TRICOR Coriolis Technology products were designed and engineered in the Germany the United States and Switzerland. Our state-of-the-art manufacturing facility in Germany is equipped with superior calibration and test equipment that guarantees performance making us a leading Coriolis flow meters manufacturer that exceeds customer expectations.

TRICOR Coriolis Technology has expanded their product portfolio of Coriolis flow meters to include three distinct product lines. The TRICOR CLASSIC Series of Coriolis flow meters is our “standard” line with lower cost and performance specs for broader market appeal. The TRICOR PRO Series is our “advanced” line with greater performance, diagnostics and connectivity options, as well as a DSP transmitter. The TRICOR SPECIALTY Series includes Coriolis flow meters that are designed for high pressure applications.

Pro-V™ Model M22-VT

Our Pro-V™ Model M22-VT inline vortex shedding flowmeters incorporate a precision 1000 Ohm Platinum RTD temperature sensor that can be used to calculate and output the compensated mass flow of saturated steam.

Features and Benefits:

 

  • Volumetric or mass flow monitoring of most liquids, gases, and steam

  • Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed devide and reduces initial cost, installation cost and cost of ownership over the lifetime of the instrument

  • Compensated mass flow reading of liquids, gases, and steam

  • Easy to install and commission

  • Highly reliable - no moving parts, no fluid to sensor contact

  • High accuracy with wide rangeability up to 100:1

  • Handles temperatures up to 750 deg F

  • Handles pressures up to 1500 psig

  • Inline configuration for pipes from 1/2 inch to 8 inches, DN15 to DN200

  • Field configurable ranges, outputs and displays

  • Remote electronics option available for use in harsh environments or locations with limited access

  • 4-20mA loop-powered mass meter design saves on energy costs

  • HART protocol communications (standard)

  • Modbus communications available

  • FM, FMC, ATEX, and IECEx Approved

     

     

     

     

     

     

     

     

     

Pro-V™ Model M23-VT

Our Pro-V Model M23-VT insertion vortex shedding flowmeters incorporate a precision 1000 Ohm Platinum RTD temperature sensor that can be used to calculate and output the compensated mass flow of saturated steam.

 

Features and Benefits:

  • Volumetric or mass flow monitoring of most liquids, gases, and steam

  • Multivariable meter delivers mass flow, temperature, pressure, and density readings from a single installed device and reduces initial cost, installation cost and cost of ownership over the lifetime of the instrument

  • Compensated mass flow reading of liquids, gases, and steam

  • Energy monitoring ability to compute and output energy use

  • Easy to install and commission – Hot tappable, process shut down not required for installation

  • Highly reliable - no moving parts, no fluid to sensor contact

  • High accuracy with wide rangeability up to 100:1

  • Handles temperatures up to 750 deg F

  • Handles pressures up to 1500 psig

  • Insertion style mounting permits installation in any pipe 2 inches and greater

  • Field configurable ranges, outputs and displays

  • Remote electronics option available for use in harsh environments or locations with limited access

  • 4-20mZ loop-powered design saves on energy costs

  • HART protocol communications (standard)

  • Modbus communications available

  • FM, FMC, ATEX, and IECEx Approved

     

Open Channel Flow Metering Package

Chaltron Systems, Inc. has designed a complete open channel flow metering system which also includes data recording.

 

Parshall Flume Features and Benefits:

  • Rigid self-supporting design for metering liquids in open channels

  • Smooth one-piece construction prevents debris build-up and reduces head loss

  • Virtually unlimited life in the measuring of sewage and industrial wastes

  • Dimensions per U.S. Dept. of Interior’s Water Measurement Manual

  • Fast delivery of most sizes

  • Embedded FRP Staff gauges calibrated in feet, tenths, and hundredths of a foot or inches and 1/4” increments

  • Stainless steel transducer brackets

  • Throat Width sizes include: 2", 3", 6", 9", 12", 18", 24", 36" and 48"

Nivelco Ultrasonic Level Sensor Features and Benefits:

  • Two-wire, loop-powered transmitter for level, volume, and open channel flow measurement

  • Menu-driven 4-push-button, 2-line x 16-character LCD user interface

  • 60 kHz transducer with 10-degree beam angle and 10" blocking distance

  • Generic Discharge Flow Equation and 35 flume/weir primary elements for open channel flow applications

  • 4-20 mA with HART

  • Accuracy of +/- 0.2% of range

CSI-Nano Paperless Recorder Features and Benefits:

  • Compact NEMA 4X enclosure with clear polycarbonate door

  • Front USB port

  • Superb full-color display

  • 4 universal inputs standard

  • Up to 30 additional virtual channels for Math, Totalizers or Counters

  • Ethernet connectivity

  • Custom alarms

  • Optional Outputs

  • Data review software for custom reviewing and report printing

  • Better recording strategy

  • Preconfigured for your application

© 2019 Chaltron Systems, Inc.  All Rights Reserved. 

The brand and product names contained within this document are trademarks or registered trademarks of their respective holders.

mcaa_proudmember2017.png